Showing 16–30 of 73 results
-
Heat Detector, Probe, Conventional
Heat Detector, Explosion Proof Thermal Sensor.
325 Deg. F (162.6 Deg. C), Tolerance +/- 10, Type 300 Stainless Steel.
5.0A @ 125VAC, Color Coding – Red.
UL & FM Approved.
M/N 27121-0. Fike
P/N 60-022 -
Heat Detector, 5603 Conventional, 2 Wire
Heat Detector, Spot 5600 Series 1 amp w/Mounting Plate & Terminals Visual Alarm Indication, Fixed Temperature 57 Deg. C, 135 Deg. F, 6-28 VDC, UL & FM Approved, (Moisture & Dustproof (Indoors) P/N 5603
-
Heat Detector, 5602 Conventional, 2 Wire
Heat Detector, Spot 5600 Series 1 amp w/Mounting Plate & Terminals Visual Alarm Indication, Rate of Rise/ Fixed Temperature 90 Deg. C, 194 Deg. F, 6-28 VDC, UL & FM Approved, (Moisture & Dustproof (Indoors))
-
Heat Detector, H365R-IV Addressable , fixed thermal sensor, LiteSpeed and CLIP
Heat Detector, Intelligent Addressable Thermal Detector, LED Current 6.5mA @ 24 VDC,Two-Wire SLC Loop Connection,15-32 VDC, Designed for Direct-Surface or Electrical-Box Mounting., Rate-of-Raise Feature, UL Listed, 4.8oz, Base Included ( B210LP) (Ivory), Honeywell P/N H365R-IV
-
Heat Detector, H365R Addressable , 135°F fixed thermal sensor, LiteSpeed only
Heat Detector, Intelligent Addressable Thermal Detector, LED Current 6.5mA @ 24 VDC,Two-Wire SLC Loop Connection,15-32 VDC, Designed for Direct-Surface or Electrical-Box Mounting., Rate-of-Raise Feature, UL Listed, 4.8oz, Base Included ( B210LP), Honeywell P/N H365R
-
Heat Detectors, 302 Series
Heat Detector, Spot 300 Series XP, 1amp Vertical Mounting, 1/2″Threads, Self-Restoring, High Temperature Rating 90 Deg.C, 194 Deg.F, 6-28 VDC, UL Approved for Class l. Gps. C&D., Class ll. Gps. E,F &G for use in Hazardous Locations, (Explosion Proof). P/N 302-EPM194
-
Heat Detectors, PHSC-356-EPR
Heat Detector, Linear Wire, Polypropylene Elastomer Jacket- Flame Retardent High resiliency: Abrasion resistance and weathering properties UL &FM Approved. XCR (356 F/180 C) Protectowire P/N. PHSC-356-XCR
-
Heat Detectors, PHSC-280-EPR
Heat Detector, Linear Wire, XCR Rating, Range: 280 Deg. F/ 138 Deg. C, Max. 93 Deg. C, Min. -40 Deg. Protectowire P/N PHSC-280-XCR
-
Heat Detectors, PHSC-280-X
Heat Detector, Linear Wire, XCR Rating, Range: 280 Deg. F/ 138 Deg. C, Max. 93 Deg. C, Min. -40 Deg. Protectowire P/N PHSC-280-XCR
-
Heat Detector, Conventional Thermal Sensor
Heat Detector, Weather Proof, 194 Deg F (90 Deg. C), 6-125 VAC/VDC, 2″ Base, Hermetically Sealed, Shock & Corrosion Resistant, Tamper Proof, UL/FM Listed, CSFM 7270-0021:001, MEA 193-03-E. Fike P/N 60-026
-
Heat Detector, Intelligent Thermal Sensor
Heat Detector, Intelligent Thermal Sensor, 135 to 190 Deg. F (57-88 Deg. C) Fixed Temp./Rate of Rise (ED-T), 15 – 30 VDC, Tri-Color Led. Fike P/N 60-1039
-
Smoke Detector, Addressable SD365 Photoelectric
Smoke Detector, Addressable Photoelectric, Low-Profile,Two Built-In Power/Sensitivity, Supervision/Alarm, LED’s, Working Voltage: 15.0-32.0 VDC installed w/B210LP Base, Ambient Temp: 32 Deg.F to 120 Deg.F (0 Deg.C to 49 Deg.C) UL & FM Approved, MEA CSFM, Honeywell P/N SD365
-
Smoke Detector, Addressable SD365-IV Photoelectric
Smoke Detector, Addressable Photoelectric, Low-Profile,Two Built-In Power/Sensitivity, Supervision/Alarm, LED’s, Working Voltage: 15.0-32.0 VDC installed w/B210LP Base, Ambient Temp: 32 Deg.F to 120 Deg.F (0 Deg.C to 49 Deg.C) UL & FM Approved, MEA CSFM, (Ivory), Honeywell P/N SD365-IV
-
Smoke Detector, Conventional Photoelectric 2W-B
Smoke Detector, Photoelectric, Automatic Sensitivity Window Verification Test, Built-In magnetic “go / no go” Detector Test Feature, Conventional Type, Two Built-In Power/Sensitivity, Supervision/Alarm, LED’s, NFPA72, Ch.7, UL & FM Approved, CSFM, Working Voltage: 15.0-33.0 VDC (Max. 42VDC), (Less Base, 2 or 4 Wire Base Compatibility). Honeywell P/N 2W-B
-
Smoke Detector, Photoelectric
Smoke Detector, Wireless Photoelectric, For use with W-GATE Wireless Gateway, B501W Base Included, Requires (4) CR-123A Batteries (included). Firelite Alarms P/N W-SD355